Functionality testing > LU-500/24S
Previous
Next
- Pass/fail indicators
- Closed-loop linear motor for car and web sense acceleration
- Tower with stable 24 pos. rotation plate
- Incremental acceleration test
- Incremental position test
- Load cell lock detection
- Skiplock detection
- Software filtering on each channel
- Acceleration corridor
- Optional doorslam test
- Graphical representation of measurements
- Results are saved in a database
- Flexible reporting with custom test report formats
- Multiple export formats for test results
Linear motor
Position range
300 mm
Position resolution
0.2 µm
Webbing sensitivity acceleration
0.01 to 10 g
Vehicle sensitivity acceleration
0.01 to 5 g
Onset
1 to 1000 g/s
Measurement
Load cell range
2000 N
Load cell resolution
0.07 N
Accelerometer range
± 10 g
Accelerometer resolution
0.001 g
Sample frequency
10 kHz
Dimensions
See images