HF-4/1SLC-XY

Durability testing  > HF-4/1SLC-XY

  • Multiple test point positions
  • Automatic test point positioning via XY table
  • Servo motor driven pushers
  • Different pusher tip attachments possible
  • Progammable pusher stop conditions:
    • On force
    • On closed contact
  • Measurement of the voltage drop over the switch
  • Measurement of the current through the switch
  • Calculation of resistance of the switch
  • Graphical representation of measurements
  • Results are saved in a database
  • Flexible reporting with custom test report formats
  • Multiple export formats for test results
  • Programmable test sequences
  • Optional CAN/LIN control
  • Station is built for climate chamber
 
Stations
Quantity
1
Lower mounting plate
500 x 500 mm
Pusher cover area
300 x 300 mm
Pushers
Pushers per station
1
Load cell range
1100 N
Load cell resolution
0.05 N
Load
up to 300 N
Positioning
Automatic
Power supply
Voltage measurement range
16 V
Voltage measurement resolution
0.25 mV
High current measurement range
5A
High current measurement resolution
75 µA
Low current measurement range
50 mA
Low current measurement resolution
0.75 µA
Programmable voltage/current
Yes
Temperature
Station temperature range
-40 to +100 °C
Dimensions
See images

Contact us for pricing or customizations