HF-422FSC

Durability testing  > HF-422FSC

  • 4 independent stations
  • 2 test point positions per station
  • Manual test point positioning with position feedback
  • Servo motor driven pushers
  • Different pusher tip attachments possible
  • Progammable pusher stop conditions:
    • On force
    • On closed contact
  • Measurement of the voltage drop over the switch
  • Measurement of the current through the switch
  • Calculation of resistance of the switch
  • Graphical representation of measurements
  • Results are saved in a database
  • Flexible reporting with custom test report formats
  • Multiple export formats for test results
  • Programmable test sequences
  • Stations are built for climate chamber
Stations
Quantity
4
Lower mounting plate
500 x 500 mm
Pusher cover area
300 x 300 mm
Pushers
Pushers per station
2
Load cell range
1100 N
Load cell resolution
0.05 N
Load
up to 300 N
Positioning
Manual
Power supply
Voltage measurement range
16 V
Voltage measurement resolution
0.25 mV
High current measurement range
5A
High current measurement resolution
75 µA
Low current measurement range
50 mA
Low current measurement resolution
0.75 µA
Programmable voltage/current
Yes
Dimensions
See images
Temperature
Station temperature range
-40 to +100 °C

Contact us for pricing or customizations