Motorized retractor testing > eEOL-1M
Previous
Next
- CAN/LIN communication with ECU
- Programming, reading and verification of ECU data
- Retractor performance tests:
- Slack removal
- Full retraction / Pre-safe
- Parking
- Haptic warning
- Retractor calibration tests:
- Speed calibration
- Torque calibration
- Measurements:
- Standby, sleeping, operating current
- Voltage over retractor
- Force on retractor
- Webbing position
- Physical spring
- 1 x 1500W power supply
- Brushless closed loop servomotors for webbing extraction
Motors
Quantity
1
Webbing extraction resolution
0.01 mm
Extraction/retraction speed
up to 2000 mm/s
CAN communication
Baud rate
up to 1 Mbs
Load
Retractor force
up to 500 N
Time to max load
less then 100 ms
Power supply
Voltage
up to 16 V
Current
up to 60 A
Current measurement
up to 50 A
Current measurement ranges
100 µA
100 mA
50 A
100 mA
50 A
Dimensions
See images